An outdoor heat pump unit mounted on a concrete pad in the front yard of a gray suburban house.

Heat Pump Repair in Bradenton, FL

Homes here need heat from January through January and cooling from March through December. If your system quits, tell us what it's doing and a licensed contractor who covers Manatee County will get in touch.

Tell us about the job

It takes about a minute.

Step 1 of 3: Equipment
An outdoor heat pump unit mounted on a concrete pad in front of a two-story suburban house with a landscaped lawn.

In Bradenton, your heat pump is the only thing standing between you and 91 degrees

Your heat pump runs almost the whole year here, cooling from March through December and covering the short, mild winter too. It barely gets a break. That kind of runtime wears on the compressor and the outdoor fan motor faster than it would somewhere with a real off season.

Most homes here run on electric heat, so when a storm knocks out power, the heat pump is down until it's back, and close to four in ten Florida households lost power for at least a day in 2024. Bradenton has seen 26 damaging wind events over the past ten years. After one hits, check the outdoor unit for debris around the coil or a fan that won't spin freely before you assume the worst.

1 months
January through January, your system heats
10 months
March through December, it cools
52°F
the average winter night it heats against
91°F
the average summer afternoon it cools against
Isometric cutaway illustration of a single-story house showing interior ductwork, an air handler and rooms, with an outdoor condenser unit connected by refrigerant lines on a plain white background.
Your system heats January through January and cools March through December.

NOAA nClimDiv, 1991–2020 normals

Florida requires HVAC contractors to hold a state license.

The Construction Industry Licensing Board tests and keeps records on the contractor, not on the individual repair. So the license tells you the business has met the state's standard, and that record exists whether the company is doing a small fix or a full install.

A heat pump repair almost always means someone has to open the refrigerant lines, and for that part of the job, federal law requires EPA Section 608 certification on top of the state license. That certification belongs to the technician doing the work, separate from the company's state license. Between the two, Florida's rule covers who is allowed to run the business, and the federal rule covers who is allowed to handle the refrigerant inside your heat pump.

Sources: Florida Legislature · Florida Department of Business and Professional Regulation

Why is my heat pump blowing cold air?
In heating mode, a heat pump does not put out air as hot as a furnace does, so it can feel cold even when it is working right. If the air is truly cold and the house is not warming up, the problem is often the reversing valve stuck in cooling mode, or the system has lost refrigerant. Ice on the outdoor unit or a breaker that keeps tripping points the same way. A contractor can check the reversing valve and refrigerant charge to find out which it is.
Why is there ice on my heat pump?
Some frost on the outdoor unit during a cold snap is normal, and the system should defrost itself and melt it off on its own. If the ice is thick, covers the coil heavily, or never goes away, the defrost cycle has stopped working or airflow across the coil is blocked. A dirty coil, a failed defrost sensor, or a fan that is not running can all cause this. Since winter lows here average 52°F, heavy icing is usually a sign something is wrong rather than just cold weather.
Why is my heat pump running but not cooling?
If the unit runs but the house is not cooling down, the most common causes are a dirty air filter blocking airflow, a low refrigerant charge, or ice built up on the indoor coil. With summer afternoons here averaging 91°F, a system that is not cooling well can fall behind fast, so it is worth checking the filter first since that is something you can do yourself. If the filter is clean and the air still is not cold, a contractor will need to check the refrigerant level and the coil.